Working principle
By fuel burner to generate high-temperature gas. And having means of heat transfer enhancement measures temperature gas stove heat conduction to the heated air, high temperature gas by the heat dissipation temperature was lowered to 250 ℃ back into the atmosphere. Be heated air through an optional blower strong into the stove, the temperature was raised after the endothermic rating discharged from the outlet of the hot air, the hot air when the temperature reaches the rated temperature limit, the burner will automatically stop burning or automatically be converted to a small flame combustion, when the hot air temperature is reduced to the lower limit of the rated temperature, the burner will re-ignite or turn fires burning, heating speed can be adjusted into the air valve opening is achieved.
Technical Specifications
Model | Burner model | Amount of fuel kg/h | Heat supply 104kcal/h | Dimensions L×W×Hmm | Hot air L×Wmm | Total weight kg |
RLY1 | RIELLO.G3/DL3FS | 1.3-1.6 | 1 | 1200×1200×1600 | Φ200 | 460 |
RLY4 | RIELLO.G10/DL10FS | 5-6.5 | 4 | 1700×1300×1600 | Φ250 | 850 |
RLY10 | RIELLO.G20/DL23FS | 13-16 | 10 | 2300×1568×1870 | Φ300 | 2200 |
RLY20 | RIELLO 1G/DL34FS | 26-32 | 20 | 2800×1568×1870 | Φ400 | 2670 |
RLY30 | RL50/DL55FT | 39-48 | 30 | 3400×1568×1870 | Φ450 | 3060 |
RLY40 | RL70/DL75FT | 52-64 | 40 | 4440×1768×2070 | Φ550 | 5600 |
RLY60 | RL100/DL100FT | 78-96 | 60 | 5140×1868×2070 | Φ600 | 8460 |
RLY100 | PRESS 4G/DL 120FT | 130-140 | 100 | 6440×2480×2300 | 550×600 | 12800 |
RLY160 | P300/DL250FT | 200-270 | 160 | 7470×2920×3480 | 750×900 | 15780 |
RLY200 | P300/DL300FT | 260-300 | 200 | 8175×2920×3480 | 750×900 | 18500 |
RLY360 | G1510 | 480-620 | 360 | 9300×2920×3480 | 21000 |